Skip to content

Stretcher route

Checks whether a flat ambulance stretcher can be carried from the entrance to each bedroom, and where it would have to be tilted.

  • Could paramedics get a stretcher to the bedroom?

For the agent, the tool is described as: Carry a flat ambulance stretcher (IBC 3002.4 size, 24 x 84 in, editable) from the main entrance to each bedroom (or named rooms) in one scan: the route, each door and turn with its margin, and a box at the tightest point per room.

Planning for an older parent, Fire captain, Older adult or family.

Input Type Required Default Notes
scan string yes Scan id. Filled from the selected building.
length_m number (m) 2.134 Stretcher length. Saved preference stretcher.length_m. Range: more than 1, at most 3.
width_m number (m) 0.61 Stretcher width. Saved preference stretcher.width_m. Range: more than 0.3, at most 1.2.
height_m number (m) 0.5 Height with the patient on it, lowered. Saved preference stretcher.height_m. Range: more than 0.1, at most 1.5.
rooms array ["Bedroom"] Room types or ids to reach.

An input that nothing fills (the selected building, a saved preference, a persona’s preset) becomes a question to the person. The agent asks only for those.

Layer Id Needed If it is missing
Wall outline matterport.walls required The verdict is unknown, with the reason.

A tool result: a verdict (pass, warn, fail or unknown), metrics, checks and findings, each with its source.

  • Draws on the building: a route with its narrow points; a box or 3D model placed in the room.
  • Panel blocks: VerdictHeader, MetricRow, CheckList, FloorPlanMini, AssumptionChips, StepLog.
  • Speed: fast. Read-only.

Stretcher route: can paramedics carry a flat stretcher from the entrance to each bedroom? The furniture_fit engine with the IBC 3002.4 stretcher, kept flat.

Sources this tool gave on the test home:

Where it came from Layer Method Reliability Note
Measured from the scan matterport geometry medium Matterport wall graph, empty rooms; door widths are the opening in the wall
Measured from the scan matterport geometry medium Right-angle corner formula on empty-room widths

The tool sets the label for each value. A model never does. The tools give a scan’s wall graph the layer matterport whichever device made the scan, so a phone scan’s geometry carries that label too.

  • Needs: wall outline. On a scan without it, the verdict is unknown and says why.
  • A result is a planning aid, not an inspection.

This section was written by running the tool when the docs were built, on a hand-made RoomPlan export (no real place was scanned), with no sponsor keys and the network switched off.

Warn Some routes are too close to call or not in the scan; measure on site.

Value Result Where it came from Reliability
Rooms reached flat 1 Measured from the scan medium
Rooms checked 2 Measured from the scan medium
Least room to spare -0.02 m Measured from the scan medium
Check Measured Against Status
To Bedroom 1, entrance door: margin 0.25 0 m pass
To Bedroom 1, doorway 1: margin 0.2 0 m pass
To Bedroom 1, doorway 2: margin 0.1 0 m pass
To Bedroom 1, turn 1 (37 degrees): margin 0.352 0 m pass
To Bedroom 2, entrance door: margin 0.25 0 m pass
To Bedroom 2, doorway 1: margin 0.15 0 m pass
To Bedroom 2, turn 1 (77 degrees): margin -0.024 0 m warn

Findings: 1 warn.

What it reported while it ran:

  1. Carried a 2.13 x 0.61 m flat stretcher to 2 rooms
threshold run stretcher_route --scan <scan-id>
curl -X POST http://127.0.0.1:8787/api/tools/stretcher_route/run -H 'content-type: application/json' -d '{...inputs}'

Over MCP the tool is named stretcher_route. See MCP server and CLI.